3.1 Minimum Night Flow (MNF)

3.1.1 Inputs

For each DMA:

  • System input volume (hourly)

3.1.2 Units

  • L/s

3.1.3 Formulas

  • \(MNF=Minimum of SIV\left(hourly\right),between 02:00-05:00\)

3.1.4 Aggregations over regional zones

  • No aggregation, as hour can differ where minimum occurs.

3.1.5 Note

  • User can change hour range.