2.1 System Input Volume (SIV, A3)¶
2.1.1 Inputs¶
For each DMA:
- NI number of inflow time series with hourly data: inflow time series 1, inflow time series 2, etc.
- NO number of outflow time series with hourly data: outflow time series 1, outflow time series 2, etc.
2.1.2 Units¶
- Input: L/s
- Output: L/s
2.1.3 Formulas¶
- \(SIV(hourly)= \sum_{i=1}^{NI}inflow_{i}(hour)-\sum_{o=0}^{NO}outflow_{o}(hour)\)
- \(SIV \left(daily\right)=\frac{\sum_{hour=1}^{24}SIV \left(hour\right)}{24}\)
2.1.4 Aggregations over regional zones¶
- Sum, both hourly and daily.
2.1.5 Notes¶
- DMAs may exist without any outflow time series.
- Another common input unit is m3/h. Here, it is expected that all inputs are in L/s and converted somewhere else.
- Commonly time series may have finer resolutions than hourly. We expect that this is converted somewhere else.