2.6 Unbilled Unmetered Consumption (UUC, A12)¶
2.6.1 Inputs¶
For each DMA:
- Data input, i.e. the unbilled unmetered consumption in m3/year.
- Seasonal factor (daily)
2.6.2 Units¶
- Input: m3/year
- Output: L/s
- Input, seasonal factor SF : [-]
2.6.3 Formulas¶
- \(UMU=UserInput (Unbilled Unmetered Consumption in\frac{m3}{yr}) \cdot (1/(365\cdot 86.4))\cdot SF(daily)\)
2.6.4 Aggregations over regional zones¶
- Sum
2.6.5 Notes¶
- Currently ignored or set to 0 in CFL.