2.5 Unbilled Metered Consumption (UMC, A11)¶
2.5.1 Inputs¶
For each DMA:
- Data input, i.e. the unbilled metered consumption in m3/year.
- Seasonal factor (daily)
2.5.2 Units¶
- Input: m3/year
- Input, seasonal factor SF : [-]
- Output: L/s
2.5.3 Formulas¶
- \(UMC=UserInput (Unbilled Metered Consumption in\frac{m3}{yr}) \cdot (1/(365\cdot 86.4)) \cdot SF(daily)\)
2.5.4 Aggregations over regional zones¶
- Sum
2.5.5 Notes¶
- Currently ignored or set to 0 in CFL.